• YEAR2005
  • LOCATIONAbu Dhabi, UAE
  • VALUESAR20.0 million
  • MANDATE PERIOD1 YEAR
  • AUTHORITYZayed Military Hospital
  • CONCESSIONAIREMultiple
  • CONSULTANTSBerlin hEART AG
  • OPERATORZMH
  • PMOUniservArabia LLC

PROGRAM DESCRIPTION

Supplier: Berlin heart AG, Germany.
Program Cost: AED20.0 Million+.
Program Completion: 2005.

The second artificial heart implantation program out of North America, Europe and Japan, under the patronage of the prince of Abu Dhabi, United Arab Emirates.

An artificial heart mechanical device was implanted for an end-stage heart failure patient.

PROGRAM TAEM

Prof. Dr. Michael Worthington, Lead Surgeon, ZMH.
Dr. Abdulla Al Nuaimi, Lead Cardiologist, ZMH.
Prof. Dr. Johannes Mueller, Berlin Heart Centre.
Ali Kilic, Technical Lead, Berlin Heart AG, Germany.
Essam K. Khalaf, MD, Lead Clinical Applications.
Eng. Omar Al Qaisy, Lead Biomedical Engineer.
Shawkatt Raghib, MD, Program Lead.

INCOR LVAD ARTIFICAL HEART IMPLANTATION PROGRAM

IINCOR® LVAD is the only third-generation implantable axial pump with magnetic impeller, certified in accordance with EU quality and safety standards.

The unique impeller suspension system works without mechanical contact and wear of components, providing long-term support of blood circulation in patients with terminal heart failure. Therefore, the INCOR® LVAD system is well suited for both temporary and final therapy (Destination therapy). The pump is made of titanium. The surface of the pump, in contact with blood, has a bioactive coating of Carmeda ® (heparin). The supply cannula connects the top of the left ventricle and the axial pump. The axial pump, in turn, is connected to the outgoing cannula through the corner section. The withdrawing cannula is anastomased with the ascending department (middle access) or the descending department (lateral access) of the aorta.

At lateral access it is possible not to use the angular section of the outgoing cannula. The pump and the control unit are connected by a control line passing through the cut of the skin. The power supply of the system is provided by two batteries (main and backup), which must be permanently connected to the control unit. The INCOR® system can also operate from AC power through the mains supply.

The control unit, main and backup batteries are stored in a lightweight, ergonomic and compact carrying case, which is fixed on the belt or over the shoulder, and also has a handle. Through the transparent window on top of the bag, you can easily perform visual control of the control unit and the appearance of alarm signals. Convenient, zip-fastened battery compartments allow you to replace the batteries with a minimal effort. The system includes a battery charger, a power supply unit and a laptop for monitoring and controlling the operation parameters of the INCOR® LVAD system. 
website

GREENVERSE CONSORTIUM (GVC) is a global program and projects management consortium founded and managed by THE D I O R GROUP for Projects Management in Middle East & Africa, 2024-2050 with BOT Projects Portfolios amounted to $50.0+bn under PMO management of THE D I O R GROUP. GVC’s Technical Consortium house the global blue-chip EPCs form USA, China and EU, while GVC’s Financial Club attracted global financing institutions and local development banks, etc. 

At GREENVERSE CNSORTIUM, we foster a platform for knowledge exchange, capacity building, ESG framework and adoption of disruptive projects management methodologies, to bridge projects lifecycle gaps in Middle East & Africa

For more information: 

THE D I O R GROUP